Villa and garden
Typical 5 × 2 m to 8 × 3 m. Delivered complete with pump, filter and fittings.
Four product lines that fit together, or that can be bought separately. Most buyers want the complete package; some export the structure only and source the plant locally.
3.5 mm hot-dip galvanized panels, bolted at flanges, braced on the outside face, waterproofed with a hot-air welded PVC liner. Panels are cut and folded in Changzhou and shipped flat.
| Panel | 3.5 mm hot-dip galvanized steel, bolted flanges |
|---|---|
| Bracing | External ribbed bracing and struts, galvanized |
| Liner | PVC, hot-air welded on site, seamless |
| Depth | 1.0 m or 2.0 m standard; other depths to project |
| Shape | Rectangular, L-shape, stepped, irregular to drawing |
| Installation | Above ground, in-ground, rooftop, inside existing buildings |
| Insulation | Optional, specified on heated pools |
| Warranty | Structure 15 years · Liner 15 years, welded seams included |
A factory-built shell delivered with its circulation system. For villas, small hotels and rooftops where the pool arrives finished rather than being built in place.
Typical 5 × 2 m to 8 × 3 m. Delivered complete with pump, filter and fittings.
Low self-weight, no wet trades on the roof slab, crane lift on the day of delivery.
Combined with heating and hydrotherapy fittings; overflow or skimmer level control.
Circulation, filtration, disinfection and water-quality control, sized from the turnover your pool needs. A 25 × 25 m competition pool and a 25 × 6 m teaching pool are not the same plant.
| Category | Typical range |
|---|---|
| Circulation pumps | 1.5–11 kW; flow up to 115 m³/h; cast iron or stainless body |
| Sand filters | Top-mount Q400–Q1400; commercial units to 354 m³/h at 50 m/h |
| Disinfection | Medium-pressure UV 30–750 m³/h; ozone generators 6–60 g/h |
| Water quality | Free chlorine 0–200 ppm, pH, ORP; two-channel dosing control |
| Heating | Air-source pool heat pumps 9–290 kW; hot-spring units to 50 °C outlet |
| Pipework & valves | UPVC 1.0 MPa and steel pipe, valves, strainers, fittings |
| Control | Pool plant panel; PLC and remote monitoring on request |
Air-source pool heat pumps from 9 kW to 290 kW, and hot-spring units to 50 °C outlet. A heat pump is selected against the heat loss of the pool — surface area, cover, air temperature, wind — not against its volume.
Single units and modular banks. Above 150 kW we usually propose multiple units with staged operation rather than one large machine.
We calculate standing loss from the water surface, evaporation, radiation to sky, walls, make-up water and pipework, then add a margin.
Staged control, flow and temperature interlocks, fault alarms. Remote monitoring by 4G available on request.
Tell us which of these two you want, and the quotation stops being a list of guesses.
Length, width and depth; what the pool is for; heated or unheated; structure only or complete plant; destination port.